CONCRETE MIX DESIGN
In freeze-thaw areas, the concrete mix design shall be a minimum 3,500 psi (24.5mpa), compressive strength shall be 3,500 psi (24.5mpa) at 28 days +. Portland Cement shall meet the requirements of ASTM-C 150. Cement content shall be 564 lbs./yd. (335 kg/m3), 1 bag fiber/yd (1 fiber bag/m3). Add Color as specified. Slump 4 inch + 1 inch (80/100mm), maximum water-cement ratio shall be .44 by weight. Coarse aggregate shall be in accordance with ASTM C 33 size 3/4" minus aggregate (14mm). Air-Entrainment 7% (+/- 1%) while using Integral Color, or 3% (+/-1%) using Color Hardeners.

In non-freeze areas the concrete mix design shall be a minimum 3,000 psi (24.5mpa), compressive strength shall be 3,000 psi (24.5mpa) at 28 days +. Portland Cement shall meet the requirements of ASTM-C 150. Cement content shall be 517 lbs./yd. (280 kg/m3), 1 bag fiber/yd. (1 bag fiber/m3). Add Color as specified. Slump 4 inch + 1 inch (80/100mm), maximum water-cement ratio shall be .44 by weight. Coarse aggregate shall be in accordance with ASTM C 33 size 3/4" minus aggregate (14mm), Air-Entrainment 7% (+/- 1%) while using Integral Color, or 3% (+/-1%) using Color Hardeners.